Microwave injector of plasma formed in a narrow coaxial resonator: Experiment and computer simulations

Under the conditions of simultaneous extraction of the ion and electron plasma components and the formation of a current-compensated plasma flow created in a narrow coaxial resonator by the ECR radiation, the radial distributions of the ion current at different mass flow rates of the working gas (argon) were obtained. The computer PIC simulations were performed using the three-dimensional numerical model in order to determine the intensity of the plasma flow as a function of the experimental parameters. © 2019 Published under licence by IOP Publishing Ltd.

Сборник материалов конференции
Издательство
Institute of Physics Publishing
Номер выпуска
1
Язык
Английский
Статус
Опубликовано
Номер
012026
Том
1383
Год
2019
Организации
  • 1 RUDN University, Moscow, Russian Federation
Ключевые слова
Direct energy conversion; Electric impedance measurement; Microwave resonators; Plasma devices; Plasma flow; Plasma jets; Coaxial resonators; Different mass; Electron plasmas; Experimental parameters; PIC simulation; Radial distributions; Simultaneous extractions; Three-dimensional numerical modeling; Plasma simulation