Dual-mode colorimetric and fluorescence biosensors for the detection of foodborne bacteria

Due to the growing demand for detection technologies, there has been significant interest in the development of integrated dual-modal sensing technologies, which involve combining two signal transduction channels into a single technique, particularly in the context of food safety. The integration of two detection signals not only improves diagnostic performance by reducing assumptions, but also enhances diagnostic functions with increased application flexibility, improved accuracy, and a wider detection linear range. The top two output signals for emerging dual-modal probes are fluorescent and colorimetric, due to their exceptional advantages for real-time sensitive sensing and point-of-care applications. With the rapid progress of nanotechnology and material chemistry, the integrated colorimetric/fluorimetric dual-mode systems show immense potential in sensing foodborne pathogenic bacteria. In this comprehensive review, we present a detailed summary of various colorimetric and fluorimetric dual-modal sensing methods, with a focus on their application in detecting foodborne bacteria. We thoroughly examine the sensing methodologies and the underlying principles of the signal transduction systems, and also discuss the challenges and future prospects for advancing research in this field. © 2023 Elsevier B.V.

Авторы
Saleh R.O. , Almajidi Y.Q. , Mansouri S. , Hammoud A. , Rodrigues P. , Mezan S.O. , Maabreh H.G. , Deorari M. , Shakir M.N. , Alasheqi M.Q.
Журнал
Язык
Английский
Статус
Опубликовано
Номер
117741
Том
553
Год
2024
Организации
  • 1 Department of Medical Laboratory Techniques, Al-Maarif University College, Al-Anbar, Iraq
  • 2 Baghdad College of Medical Sciences-Department of Pharmacy, Baghdad, Iraq
  • 3 Department of Biomedical Technology, College of Applied Medical Sciences in Al-Kharj, Prince Sattam bin Abdulaziz University, Al-Kharj, 11942, Saudi Arabia
  • 4 University of Tunis El Manar, Higher Institute of Medical Technologies of Tunis, Laboratory of Biophysics and Medical Technologies, Tunis, Tunisia
  • 5 Department of Medical and Technical Information Technology, Bauman Moscow State Technical University, Moscow, Russian Federation
  • 6 Department of Mathematics and Natural Sciences, Gulf University for Science and Technology, Mishref Campus, Kuwait
  • 7 Department of Computer Engineering, College of Computer Science, King Khalid University, KSA, Al-Faraa, Saudi Arabia
  • 8 Optical Department, College of Health and Medical Technology, Al-Ayen University, Thi-Qar, Iraq
  • 9 Republic of Iraq, Ministry of Education, Open Educational College, Studies Muthanna Centre, Iraq
  • 10 RUDN University (Peoples' Friendship University of Russia named after Patrice Lumumba), department of dermatovenerology, foreign languages, Moscow, Russian Federation
  • 11 Uttaranchal Institute of Pharmaceutical Sciences, Uttaranchal University, Dehradun, India
  • 12 Department of Medical Laboratories Technology, AL-Nisour University College, Baghdad, Iraq
  • 13 College of pharmacy/ National University of Science and Technology, Dhi Qar, Iraq
Ключевые слова
Colorimetric; Dual-mode sensor; Fluorimetric, Pathogenic bacteria
Цитировать
Поделиться

Другие записи