Experimental plasma maser as a broadband noise amplifier. I. Long pulse

Operated in the noise amplification regime, a plasma maser underwent a series of experiments. The pulse duration was 50 ns, the suppression of feedback was provided by microwave absorbers, transition from the noise amplification to a self-oscillation regime was demonstrated, and the maximum power of 10 MW with the efficiency of 3% was measured. For different plasma concentrations, the linear amplification rate was ranging from 0.1 to 0.2 cm-1. The frequency band of an emission pulse was 3-15 GHz, and the noise spectrum was stable during the pulse. The experiment provided the guidelines for further development, which are in the pulse duration reduction for abandoning the microwave absorber. The short-pulse plasma maser should be ∼35 cm long with the pulse duration < 4 ns. It will have more power and efficiency, a pulse spectrum width of 3 GHz, and tunable frequency band overlapping 3-14 GHz with the rise of plasma concentration. © 2021 Author(s).

Авторы
Buleyko A.B. 1, 2 , Ponomarev A.V.3 , Loza O.T. 1, 2 , Ulyanov D.K.3 , Andreev S.E.3
Журнал
Номер выпуска
2
Язык
Английский
Статус
Опубликовано
Номер
023303
Том
28
Год
2021
Организации
  • 1 Troitsk Institute for Innovation and Fusion Research, 12 Pushkovykh St., Troitsk, Moscow, 108840, Russian Federation
  • 2 Peoples' Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St., Moscow, 117198, Russian Federation
  • 3 Prokhorov General Physics Institute of RAS, 38 Vavilova St., Moscow, 119991, Russian Federation
Ключевые слова
Broadband amplifiers; Efficiency; Masers; Microwave oscillators; Broadband noise; Linear amplification; Microwave absorbers; Noise amplification; Plasma concentration; Pulse durations; Self-oscillations; Tunable frequency; Ultrafast lasers