Specimen tomosynthesis provides no additional value to specimen ultrasound in ultrasound-visible malignant breast lesions
Background: The aim of this study was to evaluate the accuracy and added value of specimen tomosynthesis (ST) to specimen ultrasound (SUS) in margin assessment of excised breast specimens in breast-conserving therapy for non-palpable US-visible breast lesions. Materials: Between January 2018 and August 2019, all consecutive patients diagnosed with non-palpable breast cancer visible by ultrasound (US), treated with breast-conserving surgery (BCS) and requiring radiological intraoperative breast specimen assessment, were included in this study. Excised breast specimens were examined with SUS by radiologists blinded to the ST results, and margins smaller than 10 mm were recorded. STs were evaluated retrospectively by experienced radiologists. Results: A total of 120 specimens were included. SUS showed a statistically significant correlation with pathological margin measurements, while ST did not and provided no additional information. The odds ratios (ORs) for SUS to predict a positive margin was 3.429 (confidence interval (CI) = 0.548–21.432) using a 10-mm cut-off point and 14.182 (CI = 2.134–94.254) using a 5-mm cut-off point, while the OR for ST were 2.528 (CI = 0.400–15.994) and 3.188 (CI = 0.318–31.998), respectively. Conclusions: SUS was superior in evaluating intraoperative resection margins of US-visible breast resection specimens when compared to ST. Therefore, ST could be considered redundant in applicable situations.
Авторы
Almasarweh Sa’ed1,2,3,4
,
Sudah Mazen5,6
,
Okuma Hidemi5
,
Joukainen Sarianna7
,
Vanninen Ritva5,6
,
Masarwah Amro5,6